Intumescent collar [DN50] FP6 (11220551001) 1pc.

  • Product Code: 11220551001
  • Availability: In Stock
  • Weight: 0.260 kg
  • 109.94€ (Ex Tax)
    Price without discount: 137.43€

Delivery by DHL. Delivery is available across mainland Spain, as well as the Balearic and Canary Islands, Portugal and Andorra. International shipping.

RAUPIANO PLUS System
Code 11220551001
EAN 4059757976188
Series RAUPIANO Plus
Type Intumescent collar, fireproof sleeve, firestop sleeve
Model FP6 DN50
Application Intumescent collar for built-in and surface mounting on the floor, wall, ceiling
Nominal diameter DN, mm 50
Lock type Quick closure (crab)
Material Powder-coated stainless steel / intumescent insert
Set Includes mounting hardware, assembly instructions and nameplate
Weight 0.260kg - 1pc.
Color Blue
Packaging 1pc., 28pcs. Capacity per pallet (800 x 1200): 1008pcs.
Conformity CE Marking, ETA-17/0459
Producer Rehau

The RAUPIANO PLUS system's fire resistance corresponds to class B2 (normally flammable) according to DIN 4102, Part 1.

Insulation. Fire protection measures are required when pipes cross fire-resistant building structures (e.g., firewalls, fire-resistant walls, and ceilings). However, the required fire resistance rating of the ceiling must not be compromised. Therefore, protective measures are necessary. Only the use of flame-retardant pipes (class B1) or non-combustible pipes does not require fire protection measures. When using metal sewer pipes, fire spread can occur due to the thermal conductivity of the pipes.

Fire collars. The following fire collars are used for fire protection of penetrations in walls and ceilings using RAUPIANO PLUS sewer pipes.

Fire collar system REHAU Plus:

  • Wall or ceiling installation
  • Installation in a wall or ceiling

Fire collar system REHAU Kompakt:

  • Wall or ceiling installation

Fire collar system REHAU FP:

  • FP3 - Wall or ceiling installation
  • FP6 - Wall or ceiling installation, installation in a wall or ceiling

When pipes cross ceilings, fire stops can be installed during installation or after finishing work.

* When pipes cross walls, two fire stops must be installed (on both sides of the wall). Building codes require that only fire stops with fire certification be used.

Related Products


The description and specification are presented according to the official catalogs. Trademarks, commercial names, distinctive signs, graphics, images, pictograms, technologies and other content belong to their respective owners.

The product images presented in our online store are based on actual, original product samples. However, these images are merely exemplary visual representations of the product display and do not reflect or convey the actual physical characteristics of the products or their packaging. Products may differ from those shown in the images in shape, design, color scheme, contrast, packaging size, and markings on the product or packaging, depending on the latest batch or series supplied by the manufacturer.